Last checked: · Updated:
Well water testing in Clinton County, Pennsylvania
Short answer: Pennsylvania has no statewide well testing law, so testing a Clinton County well is up to the owner.4 PA DEP recommends a yearly test for total coliform, nitrates, total dissolved solids and pH.7 In Penn State's Clinton County data, 51.0% of samples had coliform bacteria, 18.5% had E. coli and 9 of 72 arsenic samples (12.5%) were over the 0.01 mg/L standard.1
About 14,900 Clinton County residents supply their own household water, and Pennsylvania has no statewide well testing law. Penn State's lab data for the county flag bacteria most often, plus iron, manganese, corrosive water, arsenic in about one in eight samples tested for it, and some nitrate. Here's what the data show, what DEP recommends testing every year, and where to get a sample tested. Every fact has a source.
Get quotes from local well pros
- How many people here use a private well
- What tests in Clinton County have found
- Bacteria
- Arsenic
- Iron and manganese
- Nitrate
- Corrosive water and lead
- Near gas drilling or mining?
- Buying or selling a home with a well in Clinton County
- What to test and how often
- Frequently asked questions
- Where to get tested and treatment options
- Related guides
How many people here use a private well
USGS estimates that about 14,900 people in Clinton County supplied their own household water in 2015, about 38% of the county's population.2
What tests in Clinton County have found
Penn State's Agricultural Analytical Services Laboratory (AASL) summary for Clinton County covers 500 samples from 8/20/2007 to 6/27/2025:1
| Test | Counted as failing | Samples failing | Percent |
|---|---|---|---|
| Corrosivity index | below -0.5 or above 0.5 | 57 of 82 | 69.5% |
| Total coliform bacteria | present (standard: 0) | 229 of 449 | 51.0% |
| Aluminum (secondary standard) | over 0.05–0.2 mg/L | 4 of 9 | 44.4% |
| Iron (secondary standard) | over 0.3 mg/L | 26 of 89 | 29.2% |
| Manganese (secondary standard) | over 0.05 mg/L | 21 of 92 | 22.8% |
| E. coli bacteria | present (standard: 0) | 83 of 449 | 18.5% |
| pH (secondary standard) | outside 6.5–8.5 | 48 of 272 | 17.6% |
| Arsenic | over 0.01 mg/L | 9 of 72 | 12.5% |
| Zinc (secondary) | over 5 mg/L | 1 of 14 | 7.1% |
| Lead, first draw | over 0.015 mg/L | 5 of 75 | 6.7% |
| Nitrate + nitrite (as N) | over 10 mg/L | 6 of 148 | 4.1% |
| Total dissolved solids (secondary) | over 500 mg/L | 9 of 270 | 3.3% |
| Copper | over the standard | 3 of 100 | 3.0% |
| Lead, running water | over 0.015 mg/L | 0 of 75 | 0.0% |
| Barium | over 2 mg/L | 0 of 61 | 0.0% |
| Chloride (secondary) | over 250 mg/L | 0 of 49 | 0.0% |
| Sulfate (secondary) | over 250 mg/L | 0 of 28 | 0.0% |
The median pH was 7.3; the lowest sample was 4.6 and the highest 9.7. The highest arsenic result was 0.038 mg/L, nearly four times the 0.01 mg/L standard. The highest nitrate result was 34.8 mg/L (median 0.8 mg/L), the highest iron result 38.5 mg/L, the highest manganese result 14.78 mg/L and the highest first-draw lead result 0.205 mg/L.1
These are samples homeowners chose to send to one lab, not a random survey. Most of Clinton County's 500 samples were bacteria tests; only 72 were tested for arsenic and 9 to 28 for aluminum, zinc and sulfate, so treat those percentages as rough. Penn State presents the county summaries as a guide to which problems are most common locally, to help you decide what to test.4 Iron, manganese, aluminum, zinc, pH, sulfate, chloride and total dissolved solids have secondary (aesthetic) standards, not health-based limits.6
Bacteria
Total coliform bacteria were present in 229 of 449 samples (51.0%), and E. coli in 83 (18.5%).1 DEP's first item on its yearly test list is total coliform bacteria.7 If a test comes back positive, our shock chlorination guide covers disinfecting the well and retesting.
Arsenic
9 of 72 samples (12.5%) tested for arsenic were over the 0.01 mg/L standard, with a high of 0.038 mg/L.1 Arsenic isn't on DEP's yearly test list, so you have to ask for it; Penn State's WD07 Trace and WD08 Extensive packages include it.73 Our arsenic guide covers testing and treatment options.
Iron and manganese
Iron and manganese have secondary standards for staining, taste and color.6 26 of 89 samples (29.2%) were over the iron guideline and 21 of 92 (22.8%) over the manganese guideline.1 See our iron guide.
Nitrate
6 of 148 samples (4.1%) were over the 10 mg/L nitrate standard, with a high of 34.8 mg/L and a median of 0.8 mg/L.1 Nitrate is on DEP's yearly test list.7 Penn State's WD04 Agriculture/Septic package ($70) adds nitrate-nitrogen to the standard tests; the lab says nitrate may be elevated near intensively managed farmland or densely spaced or poorly working septic systems.3 Our nitrate guide covers what a high result means and treatment options.
Corrosive water and lead
57 of 82 samples (69.5%) failed the corrosivity index, and 48 of 272 (17.6%) had a pH outside 6.5–8.5, with a low of 4.6.1 First-draw lead (water that sat in the pipes) was over 0.015 mg/L in 5 of 75 samples (6.7%), with a high of 0.205 mg/L, while no running-water sample was over (0 of 75).1 Our lead guide explains first-draw vs flushed samples. Penn State's WD03 package adds corrosivity tests and both lead draws to the standard tests.3
Near gas drilling or mining?
Penn State Extension's list of pollutants to test for by nearby land use pairs gas or oil well drilling with chloride and barium, and mining with iron, manganese, sulfate and aluminum.5 Penn State's lab has packages for each: WD06 Gas/Oil Drilling (standard tests plus barium and chloride, $75) and WD05 Mining (standard tests plus aluminum, iron, manganese and sulfate, $80).3 If you're documenting water quality before or after gas drilling, the lab recommends an accredited lab that can collect the sample and provide full chain of custody, and Penn State Extension says samples meant to document existing water quality should be collected by a disinterested third party.35
Buying or selling a home with a well in Clinton County
- State rule: Penn State Extension says there are no statewide regulations requiring testing of private wells, including at sale.4 See our Pennsylvania page and the homebuyer's guide.
- What to test: DEP's yearly list (total coliform, nitrate, total dissolved solids, pH) plus what the Clinton County data flag most often: bacteria (coliform and E. coli), arsenic, iron and manganese, and a first-draw lead test.71
- Write it into the offer: because no rule requires a test, a buyer who wants one has to ask for it. Our guide covers contingency language, flow tests and negotiating.
What to test and how often
PA DEP recommends testing your well every year for total coliform bacteria, nitrates, total dissolved solids and pH, plus anything else you suspect, using a state-certified lab.7
Frequently asked questions
Is a well test required to sell a house in Clinton County, PA?
No. Penn State Extension says Pennsylvania has no statewide regulations requiring private well testing, including at sale.4
Where can I buy a bacteria test kit in Clinton County?
DEP's Moshannon District Office, which serves Cameron, Centre, Clearfield and Clinton counties, sells bacterial test kits: 814-342-8200.7
Is arsenic a problem in Clinton County wells?
Sometimes: 9 of 72 samples (12.5%) in Penn State's Clinton County data were over the 0.01 mg/L standard, with a high of 0.038 mg/L. Arsenic isn't on DEP's yearly list, so ask for it.17
Get quotes from local well pros
Need a well drilled, a pump fixed, your water tested or treated, or a well inspected for a home sale in Clinton County, Pennsylvania? Tell us what you need. With your permission, we'll try to pass your request to up to 3 local licensed or certified providers. It's free. You can also look up licensed pros yourself in our directory.
Where to get tested and treatment options
Related guides
- How to read your well water test results
- How often to test a private well
- Centre County, PA · Lycoming County, PA · Clearfield County, PA · Union County, PA · Cameron County, PA · All Pennsylvania pages
-
Penn State Agricultural Analytical Services Laboratory, "Summary of Drinking Water Samples Tested: Clinton County." https://agsci.psu.edu/aasl/water-testing/drinking-water-testing/drinking-water-test-summaries/clinton ↩↩↩↩↩↩↩↩↩↩↩
-
Dieter, C.A., and others, 2018, Estimated Use of Water in the United States County-Level Data for 2015 (ver. 2.0), U.S. Geological Survey data release (domestic self-supplied population). https://doi.org/10.5066/F7TB15V5 ↩
-
Penn State Agricultural Analytical Services Laboratory, "Drinking Water Testing" (test packages and fees). https://agsci.psu.edu/aasl/water-testing/drinking-water-testing ↩↩↩↩↩↩
-
Penn State Extension, "County Summaries of Pennsylvania Groundwater Well and Spring Data." https://extension.psu.edu/county-summaries-of-pennsylvania-groundwater-well-and-spring-data ↩↩↩↩
-
Penn State Extension, "Testing Your Drinking Water" (Table 1, pollutants associated with land uses). https://extension.psu.edu/testing-your-drinking-water ↩↩
-
U.S. EPA, "Secondary Drinking Water Standards: Guidance for Nuisance Chemicals." https://www.epa.gov/sdwa/secondary-drinking-water-standards-guidance-nuisance-chemicals ↩↩
-
Pennsylvania DEP, "Private Wells: Water Testing." https://www.pa.gov/agencies/dep/residents/my-water/private-wells/water-testing ↩↩↩↩↩↩↩↩↩↩
-