Data centers & your water — what you need to know. Send us your questions and we’ll get back to you.

Send a question FAQ: safe nearby? bill? Policy by state Audit checklist

Last checked: · Updated:

Well water testing in Cambria County, Pennsylvania

Short answer: Pennsylvania has no statewide well testing law, so testing a Cambria County well is up to the owner.4 PA DEP recommends a yearly test for total coliform, nitrates, total dissolved solids and pH.7 In Penn State's small Cambria County data set (110 samples), 55.2% of samples had coliform bacteria, 19.0% had E. coli and 30 of 35 tested were corrosive.1

About 15,500 Cambria County residents supply their own household water, and Pennsylvania has no statewide well testing law. Penn State's lab data for the county are a small set, but they flag bacteria (including E. coli) and corrosive water most often, plus manganese, iron and some lead. Here's what the data show, what DEP recommends testing every year, and where to get a sample tested. Every fact has a source.

This page can't tell you whether your water is safe to drink. Only a certified lab test of your well can do that. For bacteria test kits, call PA DEP's Cambria District Office at 814-472-1920.

Get quotes from local well pros

How many people here use a private well

USGS estimates that about 15,500 people in Cambria County supplied their own household water in 2015, about 11% of the county's population.2

What tests in Cambria County have found

Penn State's Agricultural Analytical Services Laboratory (AASL) summary for Cambria County covers 110 samples from 10/14/2007 to 5/14/2025:1

Test Counted as failing Samples failing Percent
Corrosivity index below -0.5 or above 0.5 30 of 35 85.7%
Total coliform bacteria present (standard: 0) 58 of 105 55.2%
Aluminum (secondary standard) over 0.05–0.2 mg/L 5 of 17 29.4%
Manganese (secondary standard) over 0.05 mg/L 11 of 42 26.2%
Iron (secondary standard) over 0.3 mg/L 9 of 41 22.0%
Lead, first draw over 0.015 mg/L 3 of 14 21.4%
E. coli bacteria present (standard: 0) 20 of 105 19.0%
pH (secondary standard) outside 6.5–8.5 14 of 98 14.3%
Sulfate (secondary) over 250 mg/L 2 of 19 10.5%
Chloride (secondary) over 250 mg/L 1 of 17 5.9%
Lead, running water over 0.015 mg/L 2 of 36 5.6%
Arsenic over 0.01 mg/L 1 of 29 3.4%
Barium over 2 mg/L 1 of 30 3.3%
Total dissolved solids (secondary) over 500 mg/L 3 of 94 3.2%
Nitrate + nitrite (as N) over 10 mg/L 1 of 36 2.8%
Copper over the standard 1 of 52 1.9%

The median pH was 7.1; the lowest sample was 5.5 and the highest 8.2. The highest manganese result was 12.84 mg/L and the highest iron result 61.3 mg/L. The highest running-water lead result was 0.242 mg/L, the highest sulfate result 586.6 mg/L, the highest chloride result 950.5 mg/L and the highest barium result 11.54 mg/L.1

These are samples homeowners chose to send to one lab, not a random survey. Cambria County's summary is small (110 samples, and only 14 to 42 for each metal, sulfate and chloride), so treat those percentages as rough. Penn State presents the county summaries as a guide to which problems are most common locally, to help you decide what to test.4 Iron, manganese, aluminum, pH, sulfate, chloride and total dissolved solids have secondary (aesthetic) standards, not health-based limits.6

Bacteria

Total coliform bacteria were present in 58 of 105 samples (55.2%), and E. coli in 20 (19.0%).1 DEP's first item on its yearly test list is total coliform bacteria.7 If a test comes back positive, our shock chlorination guide covers disinfecting the well and retesting.

Corrosive water and lead

30 of 35 samples (85.7%) failed the corrosivity index, and 14 of 98 (14.3%) had a pH outside 6.5–8.5.1 First-draw lead (water that sat in the pipes) was over 0.015 mg/L in 3 of 14 samples, and running-water lead in 2 of 36, with a high of 0.242 mg/L.1 A lead test should include both draws; our lead guide explains first-draw vs flushed samples. Penn State's WD03 package adds corrosivity tests and both lead draws to the standard tests.3

Iron, manganese, aluminum and sulfate

Iron, manganese, aluminum and sulfate have secondary standards for staining, taste and odor.6 11 of 42 samples (26.2%) were over the manganese guideline (high 12.84 mg/L), 9 of 41 (22.0%) over the iron guideline (high 61.3 mg/L), 5 of 17 over the aluminum guideline and 2 of 19 over the sulfate guideline (high 586.6 mg/L).1 Those four are the tests Penn State Extension pairs with mining (below).5 See our iron guide.

Arsenic, barium and nitrate

1 of 29 arsenic samples was over the 0.01 mg/L standard (high 0.027 mg/L), 1 of 30 barium samples over 2 mg/L (high 11.54 mg/L) and 1 of 36 nitrate samples over 10 mg/L (high 11.3 mg/L).1 Arsenic isn't on DEP's yearly list, so a one-time test is the only way to know; Penn State's WD07 Trace and WD08 Extensive packages include it.73 See our arsenic guide.

Near gas drilling or mining?

Penn State Extension's list of pollutants to test for by nearby land use pairs gas or oil well drilling with chloride and barium, and mining with iron, manganese, sulfate and aluminum.5 Penn State's lab has packages for each: WD06 Gas/Oil Drilling (standard tests plus barium and chloride, $75) and WD05 Mining (standard tests plus aluminum, iron, manganese and sulfate, $80).3 If you're documenting water quality before or after gas drilling, the lab recommends an accredited lab that can collect the sample and provide full chain of custody, and Penn State Extension says samples meant to document existing water quality should be collected by a disinterested third party.35

Buying or selling a home with a well in Cambria County

What to test and how often

PA DEP recommends testing your well every year for total coliform bacteria, nitrates, total dissolved solids and pH, plus anything else you suspect, using a state-certified lab.7

Frequently asked questions

Is a well test required to sell a house in Cambria County, PA?

No. Penn State Extension says Pennsylvania has no statewide regulations requiring private well testing, including at sale.4

Where can I buy a bacteria test kit in Cambria County?

DEP's Cambria District Office, which serves Cambria and Somerset counties, sells bacterial test kits: 814-472-1920.7

Is lead a concern in Cambria County wells?

In Penn State's data, first-draw lead was over 0.015 mg/L in 3 of 14 samples and running-water lead in 2 of 36, and 30 of 35 samples failed the corrosivity index. Test both draws.1

Get quotes from local well pros

Need a well drilled, a pump fixed, your water tested or treated, or a well inspected for a home sale in Cambria County, Pennsylvania? Tell us what you need. With your permission, we'll try to pass your request to up to 3 local licensed or certified providers. It's free. You can also look up licensed pros yourself in our directory.

Well Water Notebook is a free information site, not a contractor, and we can't guarantee anyone will contact you. We don't sell your details or add you to a mailing list. See our privacy policy.

Where to get tested and treatment options

DEP bacteria kits: DEP's Cambria District Office, which serves Cambria and Somerset counties, sells bacterial test kits: 814-472-1920.7

Free testing through Penn State Extension: the Pennsylvania Department of Health says it's partnering with Penn State Extension's Drinking Water Program to offer free water testing for private well owners. Ask at dehe@pa.gov or 717-787-3350.8

Penn State's lab: AASL is accredited by PA DEP for drinking water analysis. Its packages include WD01 Standard (total coliform, E. coli, pH, total dissolved solids) for $60, WD03 Aesthetics/Corrosivity plus lead for $125, WD05 Mining for $80, WD07 Trace (standard plus arsenic, barium, cadmium, chromium, copper, lead, nickel and zinc) for $130, and WD08 Extensive (which also includes arsenic, iron, manganese and nitrate) for $220.3

Accredited labs and drillers: our Cambria County directory page lists the licensed well drillers who list Cambria County among the counties they serve from the state's official lists, plus the DEP-accredited drinking water labs located in the county (two as of DEP's June 2024 list, Cardan Laboratories in Northern Cambria and RDM-Johnstown, both accredited for bacteria: total coliform/E. coli). For all DEP-accredited labs, see the Pennsylvania directory.

If a result is high: DEP says that if results exceed Pennsylvania's MCLs you should install a treatment device for that specific contaminant.7 Our guides:


  1. Penn State Agricultural Analytical Services Laboratory, "Summary of Drinking Water Samples Tested: Cambria County." https://agsci.psu.edu/aasl/water-testing/drinking-water-testing/drinking-water-test-summaries/cambria ↩↩↩↩↩↩↩↩↩↩

  2. Dieter, C.A., and others, 2018, Estimated Use of Water in the United States County-Level Data for 2015 (ver. 2.0), U.S. Geological Survey data release (domestic self-supplied population). https://doi.org/10.5066/F7TB15V5 ↩

  3. Penn State Agricultural Analytical Services Laboratory, "Drinking Water Testing" (test packages and fees). https://agsci.psu.edu/aasl/water-testing/drinking-water-testing ↩↩↩↩↩

  4. Penn State Extension, "County Summaries of Pennsylvania Groundwater Well and Spring Data." https://extension.psu.edu/county-summaries-of-pennsylvania-groundwater-well-and-spring-data ↩↩↩↩

  5. Penn State Extension, "Testing Your Drinking Water" (Table 1, pollutants associated with land uses). https://extension.psu.edu/testing-your-drinking-water ↩↩↩↩

  6. U.S. EPA, "Secondary Drinking Water Standards: Guidance for Nuisance Chemicals." https://www.epa.gov/sdwa/secondary-drinking-water-standards-guidance-nuisance-chemicals ↩↩

  7. Pennsylvania DEP, "Private Wells: Water Testing." https://www.pa.gov/agencies/dep/residents/my-water/private-wells/water-testing ↩↩↩↩↩↩↩↩

  8. Pennsylvania Department of Health, "Well Water." https://www.pa.gov/agencies/health/programs/environmental-health/well-water ↩